Description:
If your A/C hose has stainless steel inside the hose, then this Crimper can't crimp your hose!!
71500 - 001A Hydra - Krimp Pump
71500-001B Hydra-Krimp Yoke
71500-001C Complete Die Set Assembly (7 pc. set)
71500 - 6 Die Set - #6 (5/16”)
Die Set - #8 (13/32”) (Reduced Barrier)
71500 - 8 Die Set - #8 (13/32”)
71500 - 10 Die Set - #10 (1/2”)
71500 - 12 Die Set - #12 (5/8”)
71500 - 6SRB Die Set - #6 (5/16”) (Reduced Barrier)
71500 - 10SRB Die Set - #10 (1/2”) (Reduced Barrier)
71500 - 12SRB Die Set - #12 (5/8”) (Reduced Barrier)
71500-PB Custom Molded Box
Pre-operation set-up :
Open the relief valve to fully recess the piston.Then,close tightly.
Rotate the yoke fully counter clockwise to bottom out the adapter seat.
Ready To Go !
Operating Instructions :
1.Remove pin and "Open" top yoke.
2.select correct die set (refer to back page for description )
3.insert the die into joke
4.position fitting and hose in the crimper and close the yoke.
5.insert pin securely .
6.Turn Body of tool clock wise until dies are snug against hose fitting .
7.Turn hydraulic valve to "closed "position .
8.Pump handle to crimp fitting onto hose .continue pumping until handle comes to a stop
9.Once crimp is complete,turn hydraulic valve to OPEN position .
10.Turn body of tool counter clockwise until top yoke can be rotated away from piston protion of yoke
11.Romove holding pin and open yoke.
12.Remove hose assembly.